Plans Saltspring Island Chart
-
X1180-R-S00-0542 - 1RU Power Management System
This 1RU power management system designed to accommodate E-T-A type 1180 UL 1077 thermal circuit breakers with isolated A and B power regions for redundancy. The Standard 19" mounting rack chassis design is available with mounting flange options for EIA 19", 23" and ETSI standard mounting. Input terminals accept common 2-hole compression lugs up to 2/0 cable. Output terminals accepts bare wire - 20 - 12 AWG cable. A dummy breaker is available as an option when the panel is not fully populated.
-
X8340R-S00-0618-(XX) - 2RU Power Management System
This 2RU power management system is designed to accommodate E-T-A type 8340 hydraulic-magnetic, UL 1077 circuit breakers with isolated A and B power regions for redundancy. The standard 19" mounting rack chassis design is available with mounting flange options for EIA 19", 23" and ETSI standard mounting. Input terminals accept common 2-hole compression lugs up to 2 AWG cable or 2-hole narrow tongue compression lugs up to 2/0 cable. Output terminals accept standard wiring tongue terminals up to 10 AWG cable or narrow tongue up to 8 AWG. The system has an integrated voltage status indicator on each input. Options include alarm indicators and alarm outputs as well as a jumper bar for reduced input configurations.
-
X452-S00-0572-4-33X33-(XX) - 2RU Power Management System
This 2RU power management system is designed to accommodate E-T-A type 8340 hydraulic-magnetic or type 452 thermal-magnetic circuit breakers with isolated A and B power regions for redundancy. The standard 19" mounting rack chassis design is avaibale with mounting flange options for EIA 19", 23" and ETSI standard mounting. Input terminals accept common 2-hole compression lugs up to 1/0 or 2-hole flex lug up to 1 AWG. Output terminals accept Anderson PP75 quick connects.
-
X8345R-S00-0584-2-03X30-(XX)-(X)-058208 - 2RU Power Management System
This 2RU power management system is designed to accommodate E-T-A type 8345 hydraulic-magnetic, UL 489 circuit breakers (1A - 125A configuration) with isolated A and B power regions for redundancy. The standard 19" mounting rack chassis design is available with mounting flange options for EIA 19", 23" and ETSI standard mounting. Input terminals accept common 2-hole compression lugs up to 2/0 cable. Output terminals accept common 2-hole compression lugs up to 2 AWG cable. The system allows for rear and side cable access for ease of installation. An optional slide rail kit is available for ETSI and 23" versions.
-
Thermal Overcurrent Circuit Breakers Type:1410-L4
Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Miniaturised construction minimises PCB real estate required. Largely temperature-insensitive
-
Thermal Overcurrent Circuit Breakers Type:1610-21
Miniaturised single pole press-to-reset cycling trip free thermal circuit breaker designed for automotive fuse block installation.Extends the benefits of circuit breaker performance and convenience to applications which are cost critical. Colour-coded housing caps available.Version 1616 is available especially for the automotive industry (current ratings correspond to those of blade fuses).
-
Thermal Overcurrent Circuit Breakers Type: 4130
Single pole high performance thermal circuit breaker, with push-to-reset tease free, trip-free snap action mechanism (R-type TO CBE to EN 60934). Designed for threadneck panel mounting and for applications with a high fault current switching requirement.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type 201
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a narrow profile housing, recessed terminals, standard EN rail mounting, and precision CBE performance.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type:2210-T2
One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Featuring a combi-foot design for both symmetric and asymmetric rail mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. This CBE can be supplied in current ratings up to 32 A with a choice of characteristic curves. All screw terminals are recessed for safety.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type 2215-G
Miniaturised single pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Two designs provide the option of either printed circuit board or threadneck panel mounting. A separate shunt tap terminal and auxiliary contacts are available. Fast acting, medium or long delay characteristics can be specified for both models.Suitable for use in distribution rails.Complies with CBE standard EN 60934 (IEC 60935).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3120
Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 60934). The addition of a magnetic tripping module to the type 3120 range described in catalogue section Thermal Overcurrent Circuit Breakers extends the choices available (thermal-magnetic protection in pole 1, thermal or no protection in pole 2). All are offered with rocker switch or push button control - two buttons for ON/OFF or one button press-to-reset only, in designs to suit one of three different panel cut-out sizes. Illumination is optional.Approved to CBE standard EN 60934 (IEC 60934).Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3200
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, press-to-reset, snap action mechanism and additional manual release (M-type TM CBE to EN 60934). Designed for plug-in mounting with E-T-A sockets 10 and 16.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3500
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a flange for panel mounting, and optional auxiliary contacts and unprotected shunt tap terminal.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 4220-T
Single, double and three pole thermal-magnetic circuit breaker with high rupture capacity to UL 489 (5 kA), EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a choice of characteristic curves and a wide range of current ratings in finely graded steps from 0.1A through 32 A. Auxiliary contacts (make or break contacts) are optionally available. Track-mountable design, width only 12.5 mm. Ease of wiring by means of an integral busbar concept: line entry busbar LINE+ and signal busbars/signal jumpers.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 2210-S2
One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for panel or plug-in mounting. Available with auxiliary contacts (1 x N/O, 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. A choice of characteristic curves further extends the range of applications possibilities for these CBEs. Special auxiliary contact versions for industrial atmosphere and low voltages (e.g. 5 V) available on request.Approved to CBE standard EN 60934 (IEC 60934).Suitable for use in distribution rails.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 2215-L
Miniaturised single pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Two designs provide the option of either printed circuit board or threadneck panel mounting. A separate shunt tap terminal and auxiliary contacts are available. Fast acting, medium or long delay characteristics can be specified for both models.Suitable for use in distribution rails.Complies with CBE standard EN 60934 (IEC 60935).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 2216-S
One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics andoptional auxiliary contacts.Meets the requirements of the circuit breaker standard EN 60934 (IEC 60934): S-type, TM.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3120-M
Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 60934). The addition of a magnetic tripping module to the type 3120 range described in catalogue section Thermal Overcurrent Circuit Breakers extends the choices available (thermal-magnetic protection in pole 1, thermal or no protection in pole 2). All are offered with rocker switch or push button control - two buttons for ON/OFF or one button press-to-reset only, in designs to suit one of three different panel cut-out sizes. Illumination is optional.Approved to CBE standard EN 60934 (IEC 60934).Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3300, 3400 Standard Delay
Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset, snap action mechanism (R-type TM CBE to EN 60934; M-type with manual release (-H). Available with fast acting and standard magnetic tripping characteristics - types 3300 and 3400 - both with threadneck panel mounting. Options include auxiliary contacts, a separate shunt tap terminal (-A3), and pull-to-trip manual release (-H).Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3600, 3900
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Designed for plug-in mounting with E-T-A sockets 17-P10-Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips. Featuring an unprotected shunt tap terminal and optional auxiliary contacts. Type 3900 offers lower internal resistance values and is fitted as standard with auxiliary contacts and an intermediate reset position in which all contacts are isolated.Approved to CBE standard EN 60934 (IEC 60934).