Plans Saltspring Island Chart
-
SVS02 DIN RAIL MOUNT POWER DISTRIBUTION SYSTEM
The E-T-A power distribution system SVS02 is designed to accommodate the electronic circuit breaker series ESS20-003. It distributes the current supplied by a switch mode power supply up to 40 A to 4, 8, 12 or 16 channels. Mains connection is via screw terminals. The individual circuit breakers can be plugged in. Loads are connected via spring-loaded screwless terminals. The power distribution includes integral wiring of the signalisation of the individual channels which can be combined to a group signal. The SVS02 can be snapped onto a DIN symmetrical rail.Suitable for:ESS20-003ESX10-1032210-S21.3600
-
SVS04 DIN RAIL MOUNT POWER DISTRIBUTION SYSTEM
The power distribution system SVS04 for DIN hat rail mounting is designed to distribute the current supplied by a switch mode power supply to 4 or 8 positions and selectively protects the connected loads by means of the plugged in circuit breakers. With a max. load current of 8A per channel and a max. total current of 40A the power distribution system SVS04 provides ease of wiring in short circuit current limited DC24V applications. Five protected "L+ 1D load outputs per position and 15 or 30 minus terminals reduce wiring time enormously.The 4 or 8 positions accommodate the electronic circuit breaker ESS20-003, the electronic circuit protector ESX10-103, the thermal-magnetic circuit breakers 2210-S21. and 3600 as well as the adapter P10.
-
SVS09 DIN RAIL MOUNT POWER DISTRIBUTION SYSTEM
The SVS09 power distribution system with integral signalling module optimises DC 24 V distribution at the machine-oriented field level in automated process control, production plants and power plants. Offering 10-plug-in sockets for electronic and thermal-magnetic circuit breakers and an integrated alarm handling function for single and group signalisation, the SVS09 distribution board can be cascaded on the master-slave principle to meet specific requirements. This cascading allows transducers, actuators, valves, distributed PLCs, intelligent terminals etc. to be clustered into distinct function groups and to be conveniently incorporated into the plant 19s overall alarm monitoring scheme. Particularly for applications with a great number of sensors/ actuators, the SVS09 offers possibilities for cost- and space-saving in the design of control cabinets.Each load circuit that is interrupted by an overload or short circuit trip always generates a single alarm. In addition, a group alarm for the entire SVS09 cascade is induced which will be acknowledged by means of a command element (momentary switch, relay, PLC) either locally in the control cabinet or remotely in the control room. Acknowledging the group alarm immediately reactivates the group signalling function of the SVS09 cascade remobilising it for new incoming short-circuit or overload messages.The power distribution system SVS09 is mounted on a symmetrical rail and accommodates 10 electronic or thermal-magnetic circuit breakers. All terminals (line entry DC +24 V, GND (-) for self-supply, load outputs L(+), signalling and acknowledgment) are spring-loaded terminals.
-
SVS15 DIN RAIL MOUNT POWER DISTRIBUTION SYSTEM
The power distribution system SVS15 for rail-mounting distributes the voltage potentials U1 and U2, which are supplied by a DC 24 V power supply, to 8 ways ( 4 x U1, 4 x U2) and protects the connected loads selectively by means of plugged-in circuit breakers. With a maximum load current of 8 A per way and a maximum total current of 40 A the SVS15 provides ease of power distribution in short circuit limited DC 24 V applications. Five protected »L+« load outputs per way and 30 minusterminalssignificantly reduce wiring time.Suitable for the following devices:electronic circuit breaker ESS20-003..electronic circuit protector ESX10-103..thermal-magnetic circuit breaker
-
SVS14 DIN RAIL MOUNT POWER DISTRIBUTION SYSTEM
The power distribution system SVS14-10 optimises DC 24 V distribution on the field level in automated process control, industrial production and chemical plants. The system holds an integral ammeter (display 25 A) for the total current and offers ten ways for electronic and thermal-magnetic circuit breakers including group signalling. It allows protection of transformers, actuators, solenoids, peripheral PLCs, intelligent terminals etc. on the field level. Particularly for systems with a great number of sensors/actuators the SVS14 power distribution system enables a space-saving and cost-effective design of protection control cabinets.Any load circuit which might be disconnected due to overload or short circuit generates a single signal which will be summarised in a group signal directly on the power distribution system and which will be fed back directly to control.The SVS14 is a track-mountable system and accommodates 10 electronic or thermal-magnetic circuit breakers. All terminals (entry line DC +24 V, GND (-) for self-supply, load outputs L(+) and group signalling are standard screw terminals
-
SVS16 DIN RAIL MOUNT POWER DISTRIBUTION SYSTEM
The power distribution system SVS16-PB-XX provides selective overcurrent protection, powerdistribution in load circuits as well as switching and resetting of outputs.For integral consistent communication of operating and error conditions as well as switchingand resetting of individual circuits on the DC 24 V level, the system is fitted with a fully featured PROFIBUS-DP interface.The track-mountable system has 8 (SVS16-PB-08) or 16 (SVS16-PB-16) slots and accommodates electronic circuit breakers type ESX10-125 (with reset input and status output) and ESX10-115 (with control input and status output) or the solid state remote power controller E-1048-7xx (with control input and status output).
-
Power-D-Box with sockets pre-wired
The compact 19inch Power-D-Box features aluminium profiled cross members with an anodized front plate. The panel cutout accommodates up to 30 positions numbered 1 through 30. Blanks cover unused positions, with 6, 12, 24 or 30 being 1Dopen".
-
Power-D-Box with pcb-mounted sockets
The compact 2U 19inch Power-D-Box with sockets pre-wired on printed circuit board features aluminium profiled cross members with an anoodized front plate. The panel cutout accommodates up to 30 positions numbered 1 through 30. It is possible to have 6, 12, 18, 24 or 30 prepared slots or to have a redundant distribution with up to 2 x 15 positions.The Power-D-Box accommodates plug-in type circuit breakers 3600/ 3900 and 2210, solid state remote power controller E-1048-700, electronic circuit breaker type ESS20 and electronic circuit protector ESX10. The required device must be specified in the ordering information as both different installation depth and pcb pin assignments must be allowed for.The devices are plugged into corresponding sockets type 63-P10-Si (6 positions each). These sockets are soldered from the rear onto the pcb, holding a certain pre-wiring.The system is configured with redundancy as standard (2 x 15 positions), but the two groups may be interconnected so as to provide a non-redundant system if required. Line entry within each group is single pole or double pole.With single pole line entry all slot numbers per group are combined and connected via an M6 terminal stud by means of a ring cable lug.With double pole line entry, odd and even slot numbers are integrated into one circuit and connected with a 10 mm2 each.This allows use of double pole circuit breakers.Load outputs are connected by means of screw terminals up to 4 mm2 on the rear of the pcb.The system offers a number of signalisation possibilities and separation for redundancy is also possible:- series connection of make contacts (group signalisation via closed circuit current)- parallel connection of break contacts (double sided for group signalisation via closed circuit current)- parallel connection of break contacts (only one-sided, second side of break contacts will be connected individually with the terminals for single signalisation via closed or open-circuit current)Termination is on the rear side by means of screw terminals up to 1.5 mm2 (group connection) and up to 1 mm2 (single signalisation) on the pcb. When using ESS20, ESX10 or E-1048-700, the required Gnd terminals as well as control and reset signals will also be connected via the terminals for group or single signalisation.Upon request the group distribution (redundancy) can be cancelled by means of jumpers. Additional terminals on the rear side of the rack simplify connection. It is also possible to provide terminals for return lines from the individual loads so as to integrate the necessary external wiring into the rack.
-
Thermal Overcurrent Circuit Breakers Type: 104
Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934) integral type.Approved to CBE standard EN 60934 (IEC 60934). For higher current ratings see type 1140-E.
-
Thermal Overcurrent Circuit Breakers Type: 105
Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934) snap-in type.Approved to CBE standard EN 60934 (IEC 60934). For higher current ratings see type 1140-F.
-
Thermal Overcurrent Circuit Breakers Type: 127
Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type when fitted with optional manual release feature). Available in versions for plug-in or integral mounting, track mounting, or with a frame for snap-in panel mounting. The optional KF housing is particularly suited to high humidity and other damp conditions.Approved to CBE standard EN 60934 (IEC 60934).
-
SVS20 DIN RAIL MOUNT POWER DISTRIBUTION SYSTEM
The power distribution system SVS20 for rail mounting distributes the current supplied by a DC 24 V switch-mode power supply to 8 channels and selectively protects the connected loads by means of the inserted circuit breakers. With a max. load current of 8 A per channel and a max. total current of 40 A the SVS20 provides ease of wiring in short-circuit limited DC 24 V applications. Eight protected "L+ 1D load outputs per channel and 35 minus terminals help to reduce wiring time significantly.
-
Thermal Overcurrent Circuit Breakers Type: 1140-E
Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), integral type.For lower current ratings see types 104.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1140-G
Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), threadneck mounting.For lower current ratings see types 106.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1160
Thermal circuit breaker, with controlled self-resetting mechanism, specially suited to installation in inaccessible locations. Under overload conditions the circuit breaker contacts will open to protect the load circuit. A low current excitation circuit ensures that the contacts remain open thereby avoiding the hazards of automatic reset operation. The circuit breaker is reset by switching off the supply circuit for a short period. Class 2 device, contacts stay open until voltage is removed.Type II to SAE J 553.
-
Thermal Overcurrent Circuit Breakers Type: 1180
Miniaturised single pole thermal circuit breaker with switching function optional (push-push actuation). Reliable snap-acting and trip-free mechanism. Approved to CBE standard EN/IEC 60934. S type, TO.Blade terminals fitting into sockets for rail mounting.
-
Thermal Overcurrent Circuit Breakers Type: 1110
Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Featuring an ergonomically styled two colour actuator with indicator band clearly showing the tripped/OFF position.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1140-F
Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), snap-in panel mounting.For lower current ratings see type 105.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type- 1140-G15
Miniaturised double pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Threadneck panel mounting. Suitable for line and neutral switching - the thermal actuator operating on one pole simultaneously opens both poles under overload conditions.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1170
Compact single pole thermal circuit breaker with push-to-reset, tease free, trip free, snap action mechanism and separate (colour coded) manual release. Combining full feature circuit breaker protection and convenience with low cost of ownership benefits. Fitted with blade terminals for plug-in mounting.Type III to SAE J 553.Version 1176 is available especially for the automotive industry (current ratings correspond to those of blade fuses).