Circuit Protection Devices
-
Thermal Overcurrent Circuit Breakers Type: 127
Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type when fitted with optional manual release feature). Available in versions for plug-in or integral mounting, track mounting, or with a frame for snap-in panel mounting. The optional KF housing is particularly suited to high humidity and other damp conditions.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 157
Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), threadneck panel mounting. The optional -KF housing is particularly suited to high humidity and other damp conditions.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1140-E
Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), integral type.For lower current ratings see types 104.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1140-G
Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), threadneck mounting.For lower current ratings see types 106.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1160
Thermal circuit breaker, with controlled self-resetting mechanism, specially suited to installation in inaccessible locations. Under overload conditions the circuit breaker contacts will open to protect the load circuit. A low current excitation circuit ensures that the contacts remain open thereby avoiding the hazards of automatic reset operation. The circuit breaker is reset by switching off the supply circuit for a short period. Class 2 device, contacts stay open until voltage is removed.Type II to SAE J 553.
-
Thermal Overcurrent Circuit Breakers Type: 1180
Miniaturised single pole thermal circuit breaker with switching function optional (push-push actuation). Reliable snap-acting and trip-free mechanism. Approved to CBE standard EN/IEC 60934. S type, TO.Blade terminals fitting into sockets for rail mounting.
-
Thermal Overcurrent Circuit Breakers Type: 1410-L1
Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Miniaturised construction minimises PCB real estate required. Largely temperature-insensitive.
-
Thermal Overcurrent Circuit Breakers Type: 1610-92
Miniaturised single pole autoreset cycling trip free thermal circuit breaker designed for automotive fuse block installation.Extends the benefits of circuit breaker performance and convenience to applications which are cost critical.Version 1616 is available especially for the automotive industry (current ratings correspond to those of blade fuses).
-
Thermal Overcurrent Circuit Breakers Type: 1626
Single pole, thermal miniaturised circuit breaker designed for automotive applications. Fits into fuse blocks designed to ISO 8820-3, Type F.Automatic reset (for DC 12 V only) and open circuit (modified reset to SAE) version optional. Open circuit version ensures contacts staying open as long as power is on. The circuit breaker will reset after the load is removed. Particularly suitable for installation in inaccessible locations.Current ratings correspond to those of blade fuses. Clear colour coding of the ratings: blade fuse and circuit breaker of the same colour have the same rating.Meets the requirements of SAE J553.
-
Thermal Overcurrent Circuit Breakers Type: 2-5200
Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type when fitted with optional manual release feature). Designed for plug-in mounting with E-T-A sockets 10 and 16.
-
Thermal Overcurrent Circuit Breakers Type: 1610-H2
Miniaturised single pole press-to-reset cycling trip free thermal circuit breaker designed for automotive fuse block installation.Extends the benefits of circuit breaker performance and convenience to applications which are cost critical. Colour-coded manual release buttons available.Version 1616 is available especially for the automotive industry (current ratings correspond to those of blade fuses).
-
Thermal Overcurrent Circuit Breakers Type: 1620
Single pole, thermal miniaturised circuit breaker designed for automotive applications. Fits into fuse blocks designed to ISO 8820-3, Type F.Automatic reset (for DC 12 V only) and open circuit (modified reset to SAE) version optional. Open circuit version ensures contacts staying open as long as power is on. The circuit breaker will reset after the load is removed. Particularly suitable for installation in inaccessible locations.Current ratings correspond to those of blade fuses. Clear colour coding of the ratings: blade fuse and circuit breaker of the same colour have the same rating.Meets the requirements of SAE J553.
-
Thermal Overcurrent Circuit Breakers Type: 1658
Very cost effective design to meet international requirements. No exposed metal parts which are, or could become, current-carrying except for terminals. R-type TO CBE to EN 60934.- Manual reset, cycling trip free mechanism- Extremely small and lightweight- UL, CSA, VDE and EN 60934 (IEC 60934) approved
-
Thermal Overcurrent Circuit Breakers Type: 129-L11-H-KF
Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism and separate manual release (M-type TO CBE to EN 60934). Designed for bolt-on mounting with terminal block type 83-P10.
-
Thermal Overcurrent Circuit Breakers Type: 1110
Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Featuring an ergonomically styled two colour actuator with indicator band clearly showing the tripped/OFF position.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1140-F
Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), snap-in panel mounting.For lower current ratings see type 105.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 1170
Compact single pole thermal circuit breaker with push-to-reset, tease free, trip free, snap action mechanism and separate (colour coded) manual release. Combining full feature circuit breaker protection and convenience with low cost of ownership benefits. Fitted with blade terminals for plug-in mounting.Type III to SAE J 553.Version 1176 is available especially for the automotive industry (current ratings correspond to those of blade fuses).
-
Thermal Overcurrent Circuit Breakers Type: 1410-F1
Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (filament bulb for low voltages) illuminates to give a clear signal of the tripped status of the mechanism and thereby the cause of power interruption, suffix -B. Alternatively the illumination can be conventionally wired to indicate the ON status of the device, suffix -E. Returning the rocker switch through the OFF position and back ON will reset the mechanism and restore the supply. Largely temperature-insensitive.Complies with CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 2-5000
Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5000 is available with optional manual release (-H), (R-type TO CBE to EN 60934 in press-to-reset configuration; M-type when fitted with manual release -H), flange mounting. Options include an additional unprotected circuit tap (-A3).Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal Overcurrent Circuit Breakers Type: 2-5700
Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-type with push-push operation), threadneck panel mounting. Options include an additional unprotected circuit tap (-A3).Approved to CBE standard EN 60934 (IEC 60934).