Through-Hull Transducer with Depth Speed and Temperature
-
Throttle Actuator Kit 120-0055-01
-
Throttle Actuator Kit 120-0059-01
-
Third Wire Accessories
Cable Splicing and Termination Kits We offer two cable termination kits (one for plastic third wire, one for steel) and a splicing kit for plastic third wire.Head Rope Strain Reliefs We offer helical type strain reliefs for both left hand lay and right hand lay steel third wire. We also offer an 8" round and 12" round used primarily for plastic third wire.
-
Thermal Overcurrent Circuit Breakers Type:1410-L4
Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Miniaturised construction minimises PCB real estate required. Largely temperature-insensitive
-
Thermal Overcurrent Circuit Breakers Type:1610-21
Miniaturised single pole press-to-reset cycling trip free thermal circuit breaker designed for automotive fuse block installation.Extends the benefits of circuit breaker performance and convenience to applications which are cost critical. Colour-coded housing caps available.Version 1616 is available especially for the automotive industry (current ratings correspond to those of blade fuses).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type 201
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a narrow profile housing, recessed terminals, standard EN rail mounting, and precision CBE performance.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type:2210-T2
One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Featuring a combi-foot design for both symmetric and asymmetric rail mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. This CBE can be supplied in current ratings up to 32 A with a choice of characteristic curves. All screw terminals are recessed for safety.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type 2215-G
Miniaturised single pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Two designs provide the option of either printed circuit board or threadneck panel mounting. A separate shunt tap terminal and auxiliary contacts are available. Fast acting, medium or long delay characteristics can be specified for both models.Suitable for use in distribution rails.Complies with CBE standard EN 60934 (IEC 60935).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3120
Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 60934). The addition of a magnetic tripping module to the type 3120 range described in catalogue section Thermal Overcurrent Circuit Breakers extends the choices available (thermal-magnetic protection in pole 1, thermal or no protection in pole 2). All are offered with rocker switch or push button control - two buttons for ON/OFF or one button press-to-reset only, in designs to suit one of three different panel cut-out sizes. Illumination is optional.Approved to CBE standard EN 60934 (IEC 60934).Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3200
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, press-to-reset, snap action mechanism and additional manual release (M-type TM CBE to EN 60934). Designed for plug-in mounting with E-T-A sockets 10 and 16.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3500
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a flange for panel mounting, and optional auxiliary contacts and unprotected shunt tap terminal.Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 4220-T
Single, double and three pole thermal-magnetic circuit breaker with high rupture capacity to UL 489 (5 kA), EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a choice of characteristic curves and a wide range of current ratings in finely graded steps from 0.1A through 32 A. Auxiliary contacts (make or break contacts) are optionally available. Track-mountable design, width only 12.5 mm. Ease of wiring by means of an integral busbar concept: line entry busbar LINE+ and signal busbars/signal jumpers.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 2210-S2
One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for panel or plug-in mounting. Available with auxiliary contacts (1 x N/O, 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. A choice of characteristic curves further extends the range of applications possibilities for these CBEs. Special auxiliary contact versions for industrial atmosphere and low voltages (e.g. 5 V) available on request.Approved to CBE standard EN 60934 (IEC 60934).Suitable for use in distribution rails.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 2215-L
Miniaturised single pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Two designs provide the option of either printed circuit board or threadneck panel mounting. A separate shunt tap terminal and auxiliary contacts are available. Fast acting, medium or long delay characteristics can be specified for both models.Suitable for use in distribution rails.Complies with CBE standard EN 60934 (IEC 60935).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 2216-S
One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics andoptional auxiliary contacts.Meets the requirements of the circuit breaker standard EN 60934 (IEC 60934): S-type, TM.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3120-M
Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 60934). The addition of a magnetic tripping module to the type 3120 range described in catalogue section Thermal Overcurrent Circuit Breakers extends the choices available (thermal-magnetic protection in pole 1, thermal or no protection in pole 2). All are offered with rocker switch or push button control - two buttons for ON/OFF or one button press-to-reset only, in designs to suit one of three different panel cut-out sizes. Illumination is optional.Approved to CBE standard EN 60934 (IEC 60934).Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances.
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3300, 3400 Standard Delay
Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset, snap action mechanism (R-type TM CBE to EN 60934; M-type with manual release (-H). Available with fast acting and standard magnetic tripping characteristics - types 3300 and 3400 - both with threadneck panel mounting. Options include auxiliary contacts, a separate shunt tap terminal (-A3), and pull-to-trip manual release (-H).Approved to CBE standard EN 60934 (IEC 60934).
-
Thermal-Magnetic Overcurrent Circuit Breakers Type: 3600, 3900
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Designed for plug-in mounting with E-T-A sockets 17-P10-Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips. Featuring an unprotected shunt tap terminal and optional auxiliary contacts. Type 3900 offers lower internal resistance values and is fitted as standard with auxiliary contacts and an intermediate reset position in which all contacts are isolated.Approved to CBE standard EN 60934 (IEC 60934).
-
Thru Hull Intelliducer NMEA 2000